200nm-110nm Portable High Sensitivity Fiber Optic Spectrometer MAX2000-PRO
MAX2000-Pro’s fiber optic spectrometer (also known as portable spectrometer/miniature spectrometer) has high sensitivity, high quantization efficiency and high dynamic range, and is capable of responding to deep ultraviolet wavelengths (185-300nm). The MAX2000-PRO uses Hamamatsu’s back-illuminated area array FFT-CCD, which is ideal for applications that require high quantization efficiency and a wider spectrum.
MAX2000-PRO perfectly combines the Hamamatsu surface array back-illuminated FFT-CCD, and the EX grating adopts the dual flare band of 280 & 760nm, and has many advantages such as low electronic noise, high ultraviolet sensitivity, high quantization efficiency, high dynamic range and ultra-wide spectrum, etc., which is mainly used in the fields of low light detection, ultraviolet sensitivity and wide spectrum requirements.
It has the widest wavelength band of 185-1150 nm.
The MAX2000-PRO is available in the ordinary model, the EX full-spectrum model and the DUV deep ultraviolet version
Mechanical parameters
Item: Value
Size: 115*158*46.5mm
Weight: 800g
Detector parameters
Item: Value
Detector: Hamamatsu S10420-1106 back-illuminated, area array FFT-CCD
Detector response range: 185-1100nm
Effective pixels: 2048 x 64
Pixel size: 14μm
Detector area: width 28.672mm, height 0.896mm
A/D conversion: 16-bit, 500kHz
Integration time: 11 ms – 5 seconds
Sensitivity (V/lx·s): ~0.32 counts/e-
Optical system parameters
Item: Value
Optical system F/4, f/4, symmetrical crossed optical path
Focal length: 100 mm
Slit size (μm): 5, 10, 25, 50, 100, 200, etc., or no slit (customized)
Grating: Scribing grating or holographic grating with the same shining wavelength of various parameters (customizable)
Cylindrical mirror s: optional
Elimination Filters: Bandpass or longpass filters to eliminate secondary spectrum
Optical fiber and its connection interface: NA 0.22, SMA905
Spectral parameters
Item: Value
Spectral wavelength test range: 185 to 1100nm
Spectral resolution (nm): ~0.07-8.4 nm FWHM (depending on grating constant, slit width, detector model, etc.)
SNR: 500:01:00 (full scale range)
Wavelength Tolerance: Prince of Wales Hospital* 20%
Optical table: focal length 100mm, symmetrical cross CT optical path
Dynamic range: 2000:1
Stray light: < 0.05% at 600 nm; 0.10% < at 435 nm Corrected Linearity: > 99.8%
Electrical Parameters:
Item: Value
Power consumption: 500 mA×5 V DC
Data transfer rate: 3.0 ms for the full spectrum to be read into memory through the USB2.0 interface
disposition
Operating System: Windows
Data transfer interface: USB 2.0 (480Mbps), compatible with USB 1.1
System parameters are preconfigured
Part Name Customize the part parameters
Slit width: (μm) 10, 20, 50, 100, 200, etc
Number of line pairs of grating: (L/mm) 300, 400, 500, 600, 800, 1200, 1800
Spectral response range: (nm) of 200-1100 (according to grating selection)
Fiber core diameter: (μm) 9, 50, 200, 400, 600, 1000, etc
Spectral response range: (nm) 200~1100nm or 380~2500nm
Outer protective layer : normal or reinforced sheath
Interface type: SMA 905 (standard) or FC, TA, TB, TC, etc
Detector: Model Hamamatsu S10420-1106
Optional parts
Part Name :
Light sources such as deuterium halogen tungsten lamp, xenon lamp, deuterium lamp or mercury argon lamp source
Integrating sphere: used to achieve diffuse reflection, scattering, and light source homogenization output
Reflectance measurement accessories: such as integrating spheres, reflective optical fibers, standard whiteboards, aluminum mirrors, reflective brackets, special fixtures, etc
Transmittance measurement accessories: such as sample holders, transmission holders, collimators, various cuvette holders, flow-through sample cells, etc
Fluorescence excitation measurement accessories: Accessories for fluorescence excitation measurements, such as 4-way cuvette holders, etc
Packing list
Part Name Quantity
Wyoptics Micro Spectrometer MAX2000-Pro
Fiber with SMA905 interface is optional
USB cable 1
Software CD-ROM 1